{{ $t('shop.all.spaetbestellservice.hinweis') }}
Permission |
RCM mark, c UL us - Listed (OL) |
CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU-RoHS Directive |
KC-mark | KC-EMV |
Material information | RoHs compliant |
Measured parameter |
flow, temperature |
Flow direction |
P1 -> P2, Uni-directional |
Measurement process |
temperature: PT1000, Flow: Vortex |
Flow measurement range starting value [l/min] | 1,8 |
Flow measurement range end value [l/min] | 32 |
Operating pressure [bar] | 0 to 12 |
Information about operating pressure |
max. 12 bar at 40°C, max. 6 bar at 100°C |
Operating medium |
Fluid media, Neutral liquids, Water |
Information about operating and control medium | Media compatibility to the media contacting materials must be guaranteed |
Medium temperature [°C] | 0 to 90 |
ambient temperature [°C] | 0 to 50 |
Nominal temperature [°C] | 23 |
Accuracy flow value |
±2 %FS for flow <= 50 %FS, ± 3 % o.m.v. for flow >= 50 %FS |
Accuracy temperature in ± °C [°C] | 2 |
Repeatability flow value |
< ±0.5 %FS for flow <= 50 %FS, < ±1 % o.m.v. for flow >= 50 %FS |
Temperature coefficient clamp in ± %FS/K | type ±0,05%FS/K |
Control output | 2 x PNP or 2 x NPN switchable |
Switch function |
Window comparator, Threshold comparator, Freely programmable |
Switching element function | Opener/closer switchable |
Max. output current [mA] | 100 |
Analogue output |
0 - 10 V, 4 - 20 mA, 1 - 5 V |
Flow characteristic curve starting value [l/min] | 0 |
Flow characteristic curve end value [l/min] | 32 |
Max. load resistance current output [Ohm] | 500 |
Min. load resistance voltage output [kOhm] | 15 |
Short circuit resistance | yes |
Overload resistant | Available |
Report | IO-Link |
IO-Link, report | Device V 1.1 |
IO-Link, profile | Smart sensor profile |
IO-Link, function classes |
Teach channel, Diagnosis, Identification, Binary data channel (BDC), Process data variables (PDV) |
IO-Link, communication mode | COM2 (38.4 kBaud) |
IO-Link, SIO mode support | yes |
IO-Link, port type | A |
IO-Link, process data width OUT | 0 Bytes |
IO-Link, process data width IN | 5 Bytes |
IO-Link, process data contents IN |
1 bit BDC (volume monitoring), 14 bit PDV (flow measurement), 1 bit BDC (temperature monitoring), 14 bit PDV (temperature measurement), 2 bit BDC (flow measurement) |
IO-Link, service data unit IN | 32 bit Volumenmesswert |
IO-Link, minimum cycle time | 5 ms |
IO-Link, data memory needed [Byte] | 500 |
Operating voltage range DC [V] | 18 to 30 |
Reverse polarity protection | for all electrical connections |
Electrical connection |
M12x1, 5 pin, Plug straight, A-coded |
Max. line length |
30 m, 20 m For OK link operation |
installation position | arbitrary |
Fluid connection | Terminal connection DIN 32676 DN10 |
Product weight [g] | 400 |
Housing material | PA reinforced |
From medium contacting materials |
EPDM (perox.), ETFE, stainless steel, PA6T/6I reinforced |
Presentable unit(s) |
US gal, US gal/min, cft, cft/min, l, l/h, l/min, m3, °C, °F |
Protection category | IP65 |
Corrosion resistant class KBK | 3 - severe corrosion stress |
Temperature measurement range stating value [°C] | 0 |
Temperature measurement range end value [°C] | 90 |
Temperature characteristic curve starting value [°C] | 0 |
Temperature characteristic curve end value [°C] | 100 |
{{ $t('shop.all.gewicht') }} | 400 g / Stk |
{{ $t('shop.display.artikel.zollwarennummer') }} | 90261021 |
{{ $t('shop.all.hersteller') }} | Festo |
{{ $t('shop.all.spaetbestellservice.hinweis') }}
{{ $t('shop.all.wochenendversand.hinweis') }}